Fire Alarm Shop Drawings

Permit-ready, engineer-stamped fire alarm shop drawings for electrical contractors and integrators. NFPA 72 compliant. PE-stamped. Fast turnaround. Serving 24 states.

What Are Fire Alarm Shop Drawings?

Fire alarm shop drawings are the complete set of construction documents required to obtain a fire alarm permit and install a fire alarm system in a commercial building. Every Authority Having Jurisdiction (AHJ) — whether a local fire marshal, building department, or state fire office — requires a stamped, permit-ready drawing set before issuing a fire alarm permit.

NFASD produces fire alarm shop drawings that meet NFPA 72 requirements and the specific code adoptions of your local AHJ. Every drawing package is reviewed and stamped by our onboard engineering department, giving your permit submittal the credibility it needs to get approved as quick as possible.

We work directly with electrical contractors, low-voltage integrators, alarm companies, and general contractors. You upload your floor plans and project details — we will put together a professional estimate for the project. If awarded, we will deliver a complete, stamped drawing package ready for permit submittal, typically within 3–5 business days depending on the project size and complexity.

What's Included in Every Drawing Package

A complete NFASD fire alarm drawing set contains everything your AHJ requires for permit approval — no missing sheets, no back-and-forth.

Floor Plan Device Layout

Scaled floor plans showing exact placement of every smoke detector, heat detector, pull station, horn/strobe, and notification appliance — per NFPA 72 spacing and coverage rules.

Riser Diagram

Complete system riser showing head end equipment, annunciator, NAC circuits, SLC loops, and all field devices with wire types and circuit designations.

Device Schedule & Cut Sheets

Full device schedule listing every component with manufacturer, model number, and quantity. Manufacturer cut sheets included for AHJ review.

Battery Calculations

Standby and alarm load calculations per NFPA 72 requirements, confirming the panel backup batteries meets the 24-hour standby / 5-minute alarm requirement as required.(24/15 for voice evacuation)

Voltage Drop Calculations

NAC circuit voltage drop calculations ensuring notification appliances receive adequate voltage at the end of each circuit.

Wiring Diagrams

Point-to-point wiring diagrams and connection details for panel, modules, and field devices — exactly what installers need in the field.

How It Works

From PDF upload to stamped drawings in your inbox — a simple, proven process.

01

Upload Your Redlined PDFs

Send us your architectural floor plans, existing drawings, or redlined PDFs via our secure upload form. Include any AHJ-specific requirements or notes.

02

We Design Your System

Our designers lay out all devices per NFPA 72, local code, and your project specs — selecting equipment, calculating loads, and producing a complete drawing package.

03

Engineer Review & PE Stamp

A licensed Professional Engineer reviews every drawing for code compliance and stamps the package for permit submittal in your projects jurisdiction/state.

04

Receive Permit-Ready Drawings

You receive a complete, stamped drawing set ready to submit to your local AHJ. Most projects are turned around in 3–5 business days depending on size and complexity.

Why Contractors Choose NFASD

PE reviewed-stamped by a licensed engineer in your state
NFPA 72 compliant — meets AHJ requirements
Complete package: layout, riser, calcs, cut sheets
Fast turnaround — most projects 3–5 business days
All commercial building types: healthcare, education, retail, industrial & more
Serving electrical contractors in 24 states

Fire Alarm Permit Requirements

Most states and local jurisdictions require a fire alarm permit before any new installation, modification, or replacement of a fire alarm system in a commercial building. The permit application must include a complete set of shop drawings stamped by a licensed Professional Engineer.

Requirements vary by AHJ, but a typical permit submittal includes: scaled floor plan drawings showing all device locations, a system riser diagram, battery and voltage drop calculations, a device schedule with cut sheets, and a cover sheet with project information.

NFASD's engineers are familiar with the permit requirements of AHJs across all 24 states we serve. When you upload your project, let us know your AHJ and any specific requirements — we'll make sure your drawing package is complete and ready for plans review approval.

Need drawings for a specific state?

We serve electrical contractors in 24 states. Find your state for local code details and service information.

View All Service Areas

Frequently Asked Questions

What information do you need to start a fire alarm shop drawing?

We need your architectural floor plans (PDF format), the fire alarm panel model, and any AHJ-specific requirements or notes. If you have existing drawings or a redlined set, include those too. The more detail you provide, the faster we can turn your project around.

Do your fire alarm drawings include battery and voltage drop calculations?

Yes. Every drawing package includes NFPA 72-compliant battery calculations (24-hour standby / 5-minute alarm)/(24-hour standby / 15-minute alarm) for voice evacuation, and NAC circuit voltage drop calculations.

Which fire alarm panels do you design for?

We design for all major fire alarm panel manufacturers including Notifier, Simplex, EST (Edwards), Siemens, Bosch, Silent Knight, Napco, and others. If you have a preferred panel or a panel already specified for the project, just let us know.

Can you design fire alarm systems for healthcare and high-rise buildings?

Yes. We handle all commercial building types including hospitals, nursing homes, schools, high-rise office buildings, warehouses, retail centers, and industrial facilities. Healthcare and high-rise projects have additional NFPA 72 and local code requirements — our engineers are experienced with these.

What states do you provide PE-stamped fire alarm drawings for?

We currently serve 24 states: Alabama, Arizona, Arkansas, Colorado, Florida, Georgia, Indiana, Kansas, Kentucky, Louisiana, Maryland, Mississippi, New Mexico, North Carolina, Ohio, Oklahoma, Pennsylvania, South Carolina, Tennessee, Texas, Utah, Virginia, Washington DC, and West Virginia.